CVE catalog

CVE-2026-42372

D-Link DIR-605L Hardware Revision A1 (End-of-Life, EOL) contains a hardcoded telnet backdoor. The device starts a telnet daemon at boot via /bin/telnetd.sh with the username "Alphanetworks" and the st

[CVE catalog]

Severity
High · CVSS 8.8CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Published
Source
[NVD] · [CVE record]
EPSS
0.30% · Oct 25, 2026

D-Link DIR-605L Hardware Revision A1 (End-of-Life, EOL) contains a hardcoded telnet backdoor. The device starts a telnet daemon at boot via /bin/telnetd.sh with the username "Alphanetworks" and the static password "wrgn35_dlwbr_dir605l" read from /etc/alpha_config/image_sign. The custom telnetd binary accepts a -u user:password flag, and the custom login binary uses strcmp() to validate credentials. Successful authentication grants an unauthenticated attacker on the local network a root shell with full administrative control. The device has reached End-of-Life (EOL) and will not receive patches.

Vulnerable and fixed packages

Distribution-reported package versions and fixes. These do not depend on matching against the OpenFactory package catalog.

DistributionPackageReleaseVersionStatus
Cpedir-605l_firmwareNot reportedNot reportedunknown
Cpedir-605l_firmwareNot reportedNot reportedunknown

Fixed-version evidence

OpenFactory catalog packages

No matching packages in this catalog.

Observed:

References